HVAC Connector End Views
WARNING: This page is about a different car, the 2003 Saturn LW300, 2003 Saturn LW200, 2003 Saturn L300, and 2003 Saturn L200. However, it is still accessible from the selected car via links, so may be relevant.
A/C Compressor Clutch Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| A | BK | 150 | Ground |
| B | D-GN | 59 | A/C Compressor Clutch Supply Voltage |
A/C Refrigerant Pressure Sensor Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| A | BK | 552 | Low Reference (2.2L) |
| BK | 2759 | Low Reference(3.0L) | |
| B | GY | 596 | 5 Volt Reference (2.2L) |
| GY | 2709 | 5 Volt Reference (3.0L) | |
| C | RD/BK | 380 | A/C Refrigerant Pressure Sensor Signal |
Ambient Light Sensor Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| A | - | 1137 | DRL Ambient Light Sensor Signal |
| B | - | 1138 | DRL Ambient Light Sensor Low Reference |
| C | BLK | 476 | Low Reference |
| D | LT BLU/BLK | 590 | Sunload Sensor Signal |
Blower Motor Connector End View
| Insert Graphic SMCNF7123-8020 | |||
|---|---|---|---|
| Connector Part Information |
|
||
| Pin | Wire Color | Circuit Number | Function |
| A | WHT | 761 | Blower Motor Speed Control |
| B | YEL | 268 | Ignition 3 Voltage |
HVAC Control Module Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| 1 | L-BU | 61 | Ambient Air Temperature Sensor Signal |
| 2 | - | - | Not Used |
| 3 | WH | 733 | Air Temperature Door Position Signal |
| 4 | RD | 130 | 5 Volt Reference |
| 5 | BK | 476 | Low Reference |
| 6 | PU | 54 | Blower Motor Speed Request Signal |
| 7 | RD/BK | 1791 | Low Reference |
| 8 | L-BU/WH | 1318 | Mode Door Motor |
| 9 | L-GN/BK | 1648 | Recirculation Door Control |
| 10 | BU/WH | 761 | Blower Motor Speed Control |
| 11 | GY | 590 | Sunload Sensor Signal |
| 12 | - | - | Not Used |
| 13 | GN | 119 | Mode Door Position Signal |
| 14 | - | - | Not Used |
| 15 | BN | 641 | Ignition 3 Voltage |
| 16 | BK | 550 | Ground |
| 17 | OG | 1640 | Battery Positive Voltage |
| 18 | OG | 1807 | Class 2 Serial Data |
| 19 | YE | 1807 | Class 2 Serial Data |
| 20 | RD/WH | 1199 | Air Temperature Door Control |
| 21 | GY/YE | 1647 | Low Reference |
| 22 | L-GN | 1218 | Low Reference |
Mode Actuator Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| 5 | L-GN | 1218 | Low Reference |
| 6 | L-BU/WH | 1318 | Mode Door Control |
| 7 | - | - | Not Used |
| 8 | BK/WH | 550 | Ground |
| 9 | GN | 119 | Mode Door Position Signal |
| 10 | RD | 130 | 5 Volt Reference |
Blower Motor Speed Control Module Connector End View
| Insert Graphic SMCNF6101-5041 | |||
|---|---|---|---|
| Connector Part Information |
|
||
| Pin | Wire Color | Circuit Number | Function |
| 1 | BU/WH | 761 | Blower Motor Speed Control |
| 2 | PU | 54 | Blower Motor Speed Request Signal |
| 3 | BK | 550 | Ground |
Recirculation Actuator Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| 5 | GY/YE | 1647 | Low Reference |
| 6 | L-GN/BK | 1648 | Recirculation Door Control |
| 7-10 | - | - | Not Used |
Temperature Actuator Connector End View
| Connector Part Information |
|
||
|---|---|---|---|
| Pin | Wire Color | Circuit Number | Function |
| 5 | RD/BK | 1791 | Low Reference |
| 6 | RD/WH | 1199 | Air Temperature Door Control |
| 7 | - | - | Not Used |
| 8 | RD | 130 | 5 Volt Reference |
| 9 | WH | 733 | Air Temperature Door Position Signal |
| 10 | BK/WH | 550 | Ground |