Test Method (Vehicle Parked)
- Remove heated oxygen sensor.
- Insert exhaust Back Pressure Adaptor (SA9306E) into exhaust manifold. The thread designation is M18 x 1.50.
- Connect Gage Bar Kit (SA9127E), 0-15 kPa gage (0-60 in. H2O) to back pressure adaptor.
- With engine at normal operating temperature, observe exhaust back pressure at 4000 RPM.
- The exhaust back pressure must be less than 5.0 kPa (20.13 in. H2O).