Removal & Installation: Compressor: Removal
- Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. Note amount of oil removed when system is discharged.
- Rotate belt tensioner clockwise and remove compressor drive belt. Disconnect A/C compressor clutch connector. Disconnect high side (discharge) and low side (suction) hoses. Plug hoses to prevent contamination. Remove compressor bolts and compressor. Keep compressor level to avoid spilling refrigerant oil.
- Drain all oil from compressor into a clean container. Drain oil from high side port and then low side port. Measure amount of oil removed. Replace with same amount of new refrigerant oil upon installation.