Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the B10B Light/Sunload Ambient Sensor.
- Test for less than 10 Ω between the ground circuit terminal 6 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, test for less than 1V between the control circuit terminal 1 and ground.
- If greater than the specified range, test the control circuit for a short to voltage. If the circuit tests normal, replace the K9 BCM.
- Command the security LED ON. Test for B+ between the control circuit terminal 1 and ground.
- If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 BCM.
- If all circuits test normal, replace the B10B Light/Sunload Ambient Sensor.