Component Testing
- Install a 10A fused jumper wire from 12 volts to the automatic transmission shift lock actuator control circuit terminals B and E. Momentarily connect a jumper wire from ground to terminal A.
- Listen for the solenoids to turn ON and OFF.
- If the function does not perform as specified, replace the automatic transmission shift lock actuator.