Check Keyless Power Supply
Disconnect the connector from keyless buzzer.
Measure the voltage between keyless buzzer harness connector and chassis ground.
Connector & terminal
(F102) No. 2 (+) - Chassis ground (- ):
Is the voltage more than 10 V?
YES. Go to CHECK HARNESS BETWEEN KEYLESS BUZZER AND KEYLESS ENTRY CONTROL UNIT .
NO
Check the harness for open or short between fuse and keyless buzzer.