Trionic 7, Mode 06

TRIONIC 7 (MODE 06) TECHNICAL DATA

Test ID (Hex) Test limit type and Comp ID (Hex) Description Decimal range Hex range
TID 13 
1mm leak checkSaab 9-5 2000MY - 2001MY
00 EVAP monitor, small-leak factor. 0 to 65535 0000 to FFFF
01 EVAP monitor, large-leak factor. 0 to 65535 0000 to FFFF
The same value is reported in CID:s 00 and 01. When a large leak is present, both CID:s will show "Fail".
TID 13 
0.5 mm leak check Saab 9-5 2002MY - 2003MY
00 EVAP monitor, very small-leak factor. 0 to 65535  
01 EVAP monitor, small-leak factor. 0 to 65535 0000 to FFFF
02 EVAP monitor, large-leak factor. 0 to 65535 0000 to FFFF
The same value is reported in CID:s 00, 01 and 02. When a large leak is present, all CID:s will show "Fail".
TID 14  00 EVAP pressure sensor, number of flank shifts with amplitude above limit. 0 to 65535 0000 to FFFF
01 EVAP pressure sensor offset, time for signal out of limits. Value is presented in Milliseconds 0 to 65535 msec 0000 to FFFF
TID 15  00 Brake switch, number of decelerations 0 to 65535 0000 to FFFF
TID 19  80 Catalyst monitor, evaluated value 0 to 65535 0000 to FFFF
TID 1A  80 Intrusive AIR test, evaluated value 0 to 65535 0000 to FFFF
01 Main AIR test, evaluated value 0 to 65535 0000 to FFFF
TID 1C  80 Thermostat/ECT sensor test. Actual ECT reading at time of diagostic is shown. Minimum limit. 0 to 65535 ° C 0000 to FFFF
01 Thermostat/ECT sensor test. Actual ECT reading at time of diagostic is shown. Maximum limit. 0 to 65535 ° C 0000 to FFFF
TID 1D  80 Fuel tank pressure sensor adaption 0 to 65535 0000 to FFFF
Test limit type and Comp ID description
Parameter name  bit  Description 
Component ID 0 - 6 Component ID - manufacturer specified - necessary when multiple components or systems are present on the vehicle and have the same definition of Test ID.
If the same test is performed on more than one component, multiple test results shall be reported for that Test ID. For example, a test for bank 1 catalyst can be the same as a test for a bank 2 catalyst, or a test for a pre-catalyst oxygen sensor can be the same as a test for a post-catalyst oxygen sensor. In either case, a request for a single Test ID would result in two test results being reported with different Component IDs.
Test Limit Type 7 Most significant bit indicates type of test limit, where:
0 - test limit is maximum value - test fails if test value is greater than this value.
1 - test limit is minimum value - test fails if test value is less than this value.