Trionic 7, Mode 06
TRIONIC 7 (MODE 06) TECHNICAL DATA
| Test ID (Hex) | Test limit type and Comp ID (Hex) | Description | Decimal range | Hex range |
|---|---|---|---|---|
| TID 13 1mm leak checkSaab 9-5 2000MY - 2001MY |
00 | EVAP monitor, small-leak factor. | 0 to 65535 | 0000 to FFFF |
| 01 | EVAP monitor, large-leak factor. | 0 to 65535 | 0000 to FFFF | |
| The same value is reported in CID:s 00 and 01. When a large leak is present, both CID:s will show "Fail". | ||||
| TID 13 0.5 mm leak check Saab 9-5 2002MY - 2003MY |
00 | EVAP monitor, very small-leak factor. | 0 to 65535 | |
| 01 | EVAP monitor, small-leak factor. | 0 to 65535 | 0000 to FFFF | |
| 02 | EVAP monitor, large-leak factor. | 0 to 65535 | 0000 to FFFF | |
| The same value is reported in CID:s 00, 01 and 02. When a large leak is present, all CID:s will show "Fail". | ||||
| TID 14 | 00 | EVAP pressure sensor, number of flank shifts with amplitude above limit. | 0 to 65535 | 0000 to FFFF |
| 01 | EVAP pressure sensor offset, time for signal out of limits. Value is presented in Milliseconds | 0 to 65535 msec | 0000 to FFFF | |
| TID 15 | 00 | Brake switch, number of decelerations | 0 to 65535 | 0000 to FFFF |
| TID 19 | 80 | Catalyst monitor, evaluated value | 0 to 65535 | 0000 to FFFF |
| TID 1A | 80 | Intrusive AIR test, evaluated value | 0 to 65535 | 0000 to FFFF |
| 01 | Main AIR test, evaluated value | 0 to 65535 | 0000 to FFFF | |
| TID 1C | 80 | Thermostat/ECT sensor test. Actual ECT reading at time of diagostic is shown. Minimum limit. | 0 to 65535 ° C | 0000 to FFFF |
| 01 | Thermostat/ECT sensor test. Actual ECT reading at time of diagostic is shown. Maximum limit. | 0 to 65535 ° C | 0000 to FFFF | |
| TID 1D | 80 | Fuel tank pressure sensor adaption | 0 to 65535 | 0000 to FFFF |
| Test limit type and Comp ID description | ||||
| Parameter name | bit | Description | ||
| Component ID | 0 - 6 | Component ID - manufacturer specified - necessary when multiple components or systems are present on the vehicle and have the same definition of Test ID. If the same test is performed on more than one component, multiple test results shall be reported for that Test ID. For example, a test for bank 1 catalyst can be the same as a test for a bank 2 catalyst, or a test for a pre-catalyst oxygen sensor can be the same as a test for a post-catalyst oxygen sensor. In either case, a request for a single Test ID would result in two test results being reported with different Component IDs. |
||
| Test Limit Type | 7 | Most significant bit indicates type of test limit, where: 0 - test limit is maximum value - test fails if test value is greater than this value. 1 - test limit is minimum value - test fails if test value is less than this value. |
||