On-Board Diagnostics
Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
Enable criteria:
- Engine running.
Fault criteria:
- Voltage higher than 4.910 V for more than 1 s.
Dependents:
- None.
System reaction to a fault:
- A substitute value is continually calculated according to the following method: Intake air temperature at start is incremented 1°C per 60 g air mass/sec. The value is maximized to 90 °C and is used as soon as the fault criteria for the sensor is fulfilled.
OK report:
- P0116 Test 1 and Test 2 performed once and fault criteria not fulfilled. Fault criteria for P0117 or P0118 not fulfilled.
Fault handling: (For more information, see FAULT HANDLING III, OTHER EMISSION-RELATED COMPONENTS AND FUNCTION ).
- Type III.