On-Board Diagnostics
Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
Enable criteria:
- Crankshaft rotating. Main relay voltage above 6V.
Fault criteria:
- Voltage on one of the outputs below 2V if the output is not active or exceeding 2V if the output is active. Fault criteria fulfilled after 2 s.
Dependents:
- None.
System reaction to a fault:
- Closed loop is blocked.
OK report:
- Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
Fault handling: (For more information, see FAULT HANDLING III, OTHER EMISSION-RELATED COMPONENTS AND FUNCTION ).
- Type III. CHECK ENGINE does not go on.