Starter - DUCELLIER/PARIS-RHONE: Overhaul: Reassembly
- Clean all parts and coat sliding surfaces with multi- purpose grease. Assemble in reverse order of disassembly and check pinion clearance.
- Disconnect starter field terminal from solenoid and energize solenoid with 12 volt battery. Measure clearance of pinion gear to stop collar.
- Clearance should be .06" (1.5 mm). Adjust to proper clearance either by turning eccentric pin in solenoid fork or by turning adjusting screw in front of solenoid in or out.