Fault setting condition(s)
- The power supply to the DME (DFI) control unit was interrupted during control unit run-on.
or
- No or implausible time pulse from the gateway control unit within 60 seconds, with:
- Ignition on
INFORMATION
- After the ignition is switched off (terminal 15), the DME control unit switches to control unit run-on mode.
The run-on duration of the engine compartment purge fan AFTER ignition off depends on the engine compartment temperature.
- It is as follows for the following engine compartment temperatures:
- < 45 °C (113 °F) for approx. 50 seconds
- 45... 70 °C (113... 158 °F) for approx. 200 seconds
- > 70 °C (158 °F) for up to 20 minutes
- It is as follows for the following engine compartment temperatures:
- The DME control unit receives time information from the instrument cluster at regular intervals (approx. 4 sec.) when the ignition is on.
- The switch-off time A145_Time since engine stop (manual via ignition lock) comes from the instrument cluster. The gateway routes this to the DME control unit.