LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2002 >> Boxster Base, Automatic >> Repair and Diagnosis >> Electrical >> Body Electrical >> Wiring >> Measurement Of Closed-Circuit Current >> Preparations On The Vehicle >> Measurement >> Notes

Preparations On The Vehicle: Measurement: Notes

NOTE:
  • If the value of the closed-circuit current is higher than the value determined in the table, the cause must be established systematically.
  • The recommended troubleshooting procedure: With the measuring instrument connected, remove the fuse of terminal 30 and the relays one after the other. Observe the display values of the measuring instrument when removing in order to recognize a reduction in current.
  • After troubleshooting, screw the ground strap back onto the body in the proper manner.
  • The measured values could vary by approx. 20%.
  • The values listed in the table depend on the condition of the battery, the room temperature, and the engine temperature.