The operating state of the central locking system is fed back via the Door locked output and by corresponding activation of the interior light (signals 1 to 3). The operating state of the alarm system is also indicated during the inactive period by the alarm readiness display (display types 1 to 6). It is indicated exclusively by the alarm readiness display at the end of the inactive period. Displayed system faults are always current faults. Previous system faults entered in the status memory have no influence on the function display.
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 1 (NORMAL FLASHING)
| Display type 1 (normal flashing) |
| Requirement: |
Alarm system primed. No alarm output or no active alarm input after re-locking if no alarm input is active. |
| Duration: |
Until deactivation, then display type 6. |
| LED flashes with a frequency of 0.5 Hz |
| On time |
100 ms |
| Off time |
1900 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 2 (DOUBLE FLASHING)
| Display type 2 (double flashing) |
| Requirement: |
After alarm output or active alarm input after activation or re-locking. |
| Duration: |
Until deactivation, then display type 6. |
| LED flashes with a frequency of 0.5 Hz |
| On time 1, 2 |
100 ms |
| Off time 1 |
200 ms |
| Off time 2 |
1700 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 3 (RAPID FLASHING)
| Display type 3 (rapid flashing) |
| Requirement: |
Alarm system primed. No active alarm inputs. |
| Duration: |
Inactive period, then display type 1. |
| LED flashes with a frequency of 2 Hz |
| On time |
100 ms |
| Off time |
400 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 4 (RAPID FLASHING)
| Display type 4 (rapid flashing) |
| Requirement: |
Reception of an adapted hand-held transmitter. |
| Duration: |
Push of the button. |
| LED flashes with a frequency of 10 Hz |
| On time |
50 ms |
| Off time |
50 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 5 (ON)
| Display type 5 (on) |
| Requirement: |
After central locking system emergency locking or after locking command is given twice via hand-held transmitter or door lock. |
| Duration: |
For inactive period during central locking system emergency locking, then display type 2 for inactive period for locking command given twice, then display type 1. |
| The LED is continuously on. |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - DISPLAY TYPE 6 (OFF)
| Display type 6 (OFF). |
| The LED is not switched on. |
In addition, the checkback of faults and of the standard status is performed with signal 3 at the interior light output. An audible checkback via the alarm horn output also takes place at the alarm control module, together with a visual checkback via the outputs for the direction indicator lights.
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - SIGNAL 1
| Signal 1: |
| The outputs are triggered once. |
| On time |
50 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - SIGNAL 2
| Signal 2: |
| The outputs are triggered twice. |
| On time 1, 2 |
50 ms |
| Off time |
200 ms |
FUNCTION DISPLAY AND AUDIBLE CHECKBACK - SIGNAL 3
| Signal 3: |
| The outputs are triggered once. |
| On time |
2500 ms |
These functions can be switched on and off with the Porsche System Tester II 9588, depending on the country variants. The times are freely programmable.
Assignment of the display type of the alarm readiness light to the operating state.
ASSIGNMENT OF DISPLAY TYPE OF ALARM READINESS LIGHT TO OPERATING STATE
| Operating conditions: |
Display type: |
Operating state: |
| During inactive period |
| Self-test OK, central locking system locked and secured, all inputs in normal position, not locked 3x. |
Rapid flashing (3) |
Not primed |
| Self-test OK, central locking system locked, all inputs in normal position, not locked 3x. |
On (5) |
Not primed |
| Self-test not OK. |
Off (6) |
Not primed |
| Self-test OK, central locking system must not be locked, not locked 3x. |
Off (6) |
Not primed |
| Self-test OK, central locking system locked, active inputs. |
Off (6) |
Not primed |
| Self-test OK, locking/priming by locking 3x. |
On (5) |
Not primed |
| Inactive period expired. |
| All inputs inactive, central locking system locked and secured, not locked 3x, no alarm. |
Normal flashing (1) |
Primed |
| All inputs inactive, central locking system locked, no alarm, not locked 3x. |
Normal flashing (1) |
Primed |
| Inputs active. |
Double flashing |
Primed for all inactive inputs |
| During or after alarm output. |
Double flashing |
Primed |
| Priming/locking command by 3x rapid locking of the system. |
Double flashing (2) |
Primed |
| Self-test not OK. |
Off (6) |
Not primed |
If a control command is issued via the hand-held transmitter, this is confirmed with display type 4 for the duration of the operation. This display has priority.