Possible causes, elimination, notes
If there is a short to B+ on pressure regulator 4, the torque converter clutch will always stay open.
NOTE:
The pressure regulators (DRs) are pressure-control solenoid valves. They convert an electrical current to a proportional hydraulic pressure.
- Check pressure regulator with wiring. To do this, connect an ohmmeter to the control module connector and measure the resistance:
- DR1 = Pin 52 and pin 5
- DR2 = Pin 52 and pin 1
- DR3 = Pin 52 and pin 29
- DR4 = Pin 52 and pin 4
Nominal value: 5 ... 10 ohm
- Check wiring from the control module connector pins 1, 4, 5 and 29 to the 16-pole transmission connector pins 3, 11, 2 and 7 for continuity, short to ground and short to B+.
- Check the pressure regulator. To do this, remove the ATF pan, pull off plug connection on the pressure regulator and measure the resistance.
Nominal value: 5-10 ohm
NOTE:
The hydraulic control unit must be removed before the DR4 (modulation pressure) can be tested.