Cold Enrichment System
An electric switching valve is installed in vacuum line for retard control in order to also have proper emissions in the warm-up phase. This valve receives power from the acceleration enrichment control unit in the first minute after a cold start below 98°F (30°C) and stops vacuum. This advances the ignition timing, through which the idle speed is faster and emission control better.