Typical Scan Tool Data
HO2S Heater Bank Sensor 1
| Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
|---|---|---|---|---|
| HO2S Heater Voltage Supply | Approximately 0.5-2.0 A | 0.00 A | 0.00 A | Approximately 0.5-2.0 A |
| HO2S Heater Voltage Supply | 7-100% | 7% | 7% | 7-100% |
| HO2S Heater Low Control | Approximately 0.5-2.0 A | 0.00 A | 0.00 A | 0.00 A |
| HO2S Heater Low Control | 7-100% | 7% | 7% | 7% |