Circuit/System Testing
- Ignition OFF, disconnect the X3 harness connector at the BCM.
- Verify that a test lamp illuminates between the fuse B+ circuit terminal 3 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, connect the X3 harness connector at the BCM.
- Disconnect the harness connector at the turn signal/multifunction switch.
- Ignition ON, test for B+ between the B+ circuit terminal 6 and ground.
- If less than the specified value, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.