FTP Sensor
- Ignition ON and fuel cap removed, verify that the FTP sensor parameter is between 1.3-1.7 volts.
- If the FTP sensor parameter is not within the specified range, test the FTP low reference circuit for an open or high resistance. If the circuit tests normal, replace the FTP sensor.
- With the GE-41415-50 , connect the J 41413-200 to the fuel filler neck. See Special Tools .
- Start the engine.
- Allow the engine to idle.
- Use the Purge/Seal function to seal the system with a scan tool.
- Command the EVAP canister purge solenoid valve to 20 percent.
- Observe the vacuum/pressure gage on the J 41413-200 and the FTP parameter on the scan tool. See Special Tools .
- Verify that the vacuum increases to the abort limit on the scan tool or more than 3.2 volts, and the value is closely similar between the scan tool and the vacuum/pressure gage on the J 41413-200
. See Special Tools
.
- If the values are not similar or the voltage is not within the specified range, replace the FTP sensor.
IMPORTANT:
Refer to the J 41413-200
operation manual for detailed instructions. See Special Tools
.