Component Testing
- Install a 3A fused jumper wire between the Yaw and Lateral Accelerometer Sensor Volt reference terminal 1 and 5 volts. Install a jumper wire between the low reference circuit terminal 6 and ground.
- Sweep the sensor through the entire range while monitoring the resistance between the signal circuit terminal 5 and the low reference circuit terminal 6. The voltage should vary between 0.25-4.75 volts without any spikes or dropouts.
- If not within the specified range or is erratic, replace the Yaw and Lateral Accelerometer Sensor.