Main Power Window Switch
- Ignition OFF, disconnect the harness connector at the Main Power Window switch.
- Test for infinite resistance between the signal terminals 2 and 5 and the B+ circuit terminal 2 with the LR Switch in the INACTIVE position.
- If less than infinite resistance, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 2 and the B+ circuit terminal 2 with the switch in the UP position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 5 and the B+ circuit terminal 2 with the switch in the DOWN position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for infinite resistance between the signal terminals 3 and 3 and the B+ circuit terminal 2 with the RR Switch in the INACTIVE position.
- If less than infinite resistance, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 3 and the B+ circuit terminal 2 with the switch in the UP position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 3 and the B+ circuit terminal 2 with the switch in the DOWN position
- If greater than the specified range, replace the Main Power Window switch.
- Test for infinite resistance between the signal terminals 5 and 6 and the B+ circuit terminal 2 with the Front Passenger Switch in the INACTIVE position.
- If less than infinite resistance, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 5 and the B+ circuit terminal 2 with the switch in the UP position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 6 and the B+ circuit terminal 2 with the switch in the DOWN position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for infinite resistance between the signal terminals 5 and 4 and the B+ circuit terminal 2 with the Driver Switch in the INACTIVE position.
- If less than infinite resistance, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 5 and the B+ circuit terminal 2 with the switch in the UP position.
- If greater than the specified range, replace the Main Power Window switch.
- Test for less than 2 ohms of resistance between the signal terminal 4 and the B+ circuit terminal 2 with the switch in the DOWN position.
- If greater than the specified range, replace the Main Power Window switch.