Installation Procedure
- Install the ground cable.
- Install the nut to retain the ground cable to the bellhousing stud.
Tighten: Tighten the ground cable nut to 25 N.m (18 lb ft).
- Install the front transmission mount. Refer to Transmission Mount Replacement - Front in Automatic Transaxle - 4T40-E/4T45-E.
- Install the lower closeout panel. Refer to Radiator Air Baffle and Deflector Replacement - Side in Engine Cooling.
- Lower the vehicle.
- Install the negative cable to the retainers.
- Tape the positive cable and the ground strap to the negative cable.
- Install the bolt to retain the ground cable to the core support.
- Connect the negative ground cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.