Installation Procedure
- Install the secondary AIR pressure sensor (2) to the shut off valve (3) with the one fastener (4).
- Tighten the secondary AIR pressure sensor fastener (4).
Tighten: Tighten the fastener to 8.8 N.m (77 lb in).
- Connect the electrical connector (1) to the AIR pressure sensor (2).
NOTE:
Refer to Fastener Notice in Cautions and Notices.
- Install the secondary AIR pressure sensor (2) to the shut off valve (3).
- Secure the secondary AIR pressure sensor with two fasteners.
Tighten: Tighten the fasteners to 5.0 N.m (44 lb in).
- Connect the electrical connector (1) to the AIR pressure sensor (2).
NOTE:
Refer to Fastener Notice in Cautions and Notices.