Installation Procedure
- Install the auxiliary intake air control solenoid (3) to the air cleaner housing with the two fasteners (4).
Tighten: Tighten the fasteners to 3.7 N.m (33 lb in).
- Connect the 2 vacuum hoses (2) to the auxiliary intake air control solenoid (3).
- Connect the electrical connector.
NOTE:
Refer to Fastener Notice in Cautions and Notices.