LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2004 >> Aztek Base, AWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Description and Operation >> Load Shed System Description and Operation >> Load-Shed

Load Shed System Description and Operation: Load-Shed

This vehicle uses the following load-shed actions:

Load Shed System Description and Operation

Load Shed Level Affected Systems Action Taken
Load-Shed Level 0 No systems affected Normal operation
Load-Shed Level 1 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Cycled at 80% duty cycle, OFF for 4 of every 20 second cycle. Indicator and timer not affected.
Message Center, Instrument Cluster No messages or indicators are displayed. Data (DPID) indicating that the Load-Shed 1 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated load-shed 1 action or with a battery disconnection.
Load-Shed Level 2 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Cycled at 50% duty cycle, OFF for 10 of every 20 second cycle. Indicator and timer not affected.
Message Center, Instrument Cluster "Battery Saver Action" message or flashing indicators is displayed. Data (DPID) indicating that the Load-Shed 2 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated load-shed 2 action or with a battery disconnection.
Load-Shed Level 3 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Turned OFF. Indicator and timer are not affected. The indicators and timers are not controlled by the BCM. The operator must turn ON system when load-shed level is exited. System will not respond to operator input until current load-shed level is exited. This system will respond to only one Load-Shed Level 3 command per ignition switch cycle.
Message Center, Instrument Cluster "Battery Saver Action" message is displayed. Battery/Charging System Failure icon is illuminated. Chime may be activated constantly until the load-shed level is exited. Data (DPID) indicating that the Load-Shed Level 3 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated Load-Shed 3 actions or with a battery disconnection.