Initialization Sequence
The EBCM performs one initialization test each ignition cycle. The initialization of the EBCM occurs when one set of the following conditions occur:
Both of the following conditions occur:
- The EBCM receives that there is a minimum of 500 rpm from the PCM via class 2 serial data message.
- The stoplamp switch is not applied.
or
Both of the following conditions occur:
- The vehicle speed is greater than 16 km/h (10 mph).
- The stoplamp switch is applied.
The initialization sequence may also be commanded with a scan tool.
The initialization sequence cycles each solenoid valve and the pump motor (as well as the necessary relays) for approximately 1.5 seconds to check component operation. The EBCM sets a DTC if any error is detected. The initialization sequence may be heard and felt while it is taking place, and is considered part of normal system operation.
The EBCM defines a drive cycle as the completion of the initialization sequence.