Test Description
The numbers below refer to the step numbers in the diagnostic procedures.
- 4 - This step verifies EVAP canister purge solenoid electrical operation.
- 5 - This step tests EVAP canister purge solenoid function.
- 8 - This step uses EVAP Purge/Seal function to test EVAP canister vent solenoid, pressure switching solenoid, and purge solenoid for correct operation. Using EVAP Purge/Seal function also tests for leaks by allowing the technician to seal the system and monitor FTP sensor.
- 9 - This step tests EVAP canister vent valve and hoses for a blockage or restriction. If vacuum does not drop to less than -10.0 in. H2O after 30 seconds, there is a faulty condition in EVAP vent system. EVAP vent portion of EVAP control system is diagnosed in DTC P0446.
- 21 - This step uses EVAP Purge/Seal function to test EVAP canister vent solenoid, pressure switching solenoid, and purge solenoid for correct operation. Using EVAP Purge/Seal function also tests for leaks by allowing the technician to seal the system and monitor FTP sensor.