Circuit Description
PCM provides about 0.45 volt reference to Heated Oxygen Sensor (HO2S). HO2S sensor signal voltage varies from about one volt when exhaust is rich to about 0.1 volt when exhaust is lean. PCM counts number or times a rich-to-lean and lean-to-rich response is indicated and adds amount of time it takes to complete all transitions. PCM uses this information to determine average time for each transition. If average response time is slow, DTC P0133 will set.