DTC 82, Calibration Memory Failure: Notes
This test allows EBCM to check for a calibration failure by comparing calibration value to a known value stored in EEPROM. This test is also used to prevent incorrect use of calibrations or changes to calibrations that may alter designed function of ABS.
NOTE:
Test number refers to number on diagnostic chart. To identify circuits and terminals referenced in text and flowcharts, see WIRING DIAGRAM
.
- Tests for fault during diagnosis. If fault is present, replace EBCM.