Hazard Warning Switch
- Disconnect wiring from hazard flasher switch. See INSTRUMENT PANEL article in the ACCESSORIES/SAFETY EQUIPMENT section. Set switch to OFF position.
- Continuity should not exist between terminals No. 3 (Red Yellow wire on mating connector) and No. 4 (single Blue wire on mating connector). Continuity should exist between terminals No. 2 (2 Blue wires on mating connector) and No. 4 (single Blue wire on mating connector). Continuity should not exist between terminal No. 9 (Purple wire on mating connector) and terminals No. 6 and No. 8 (Brown wires on mating connector).
- Set switch to ON position. Continuity should exist between terminals No. 3 (Red Yellow wire on mating connector) and No. 4 (single Blue wire on mating connector). Continuity should not exist between terminals No. 2 (2 Blue wires on mating connector) and No. 4 (single Blue wire on mating connector). Continuity should exist between terminal No. 9 (Purple wire on mating connector) and terminals No. 6 and No. 8 (Brown wires on mating connector).