Hold-In Winding
- Connect ammeter in series with a 12-volt battery and "S" terminal on solenoid. See Fig 1. Connect a voltmeter between solenoid "S" terminal and ground. Connect a carbon pile across battery.
- Adjust voltage to 10 volts. Ammeter should indicate 13-19 amps.