Code 45 - Rich Exhaust Indication (A/J/N/P Body): Notes
The ECM supplies a voltage of about .45 volts between circuits No. 412 and 413. The O2 sensor varies the voltage from one volt (rich exhaust) to .10 volt (lean exhaust). The sensor acts like an open sensor circuit and produces no voltage when exhaust temperature is below 600°F (316°C). An open sensor circuit or cold sensor causes open loop operation.
Code 45 is set when O2 sensor signal at ECM is above .75 volts for 50 seconds and time since engine start is one minute or more. Code 45 indicates a rich exhaust and diagnosis should begin with these items: fuel pressure, leaking injector, HEI shielding, canister purge saturation, coolant sensor, MAP sensor, O2 sensor contamination and TPS intermittent output.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Checks to see if O2 sensor is registering a rich condition.