Functional Test
- To check proper operation, connect timing light and check timing at normal operating temperature. Adjust if necessary. See appropriate article in TUNE-UP PROCEDURES section.
- Detach connector from temperature switch at water outlet housing. Engine timing should remain at specification.
- Ground temperature switch connector. Timing should decrease by about 6 degrees. If not, check hoses and wiring for proper condition and connections. If hoses and wiring are okay, test solenoids, relay and distributor dual diaphragm vacuum advance unit.