LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 1972 >> Firebird Base, 7.5L Eng VIN T, Not Available Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Automatic Temperature Control >> New Feature Note

New Feature Note

LOW REFRIGERANT CHARGE PROTECTION:  This system protects the compressor from damage in the event the refrigerant charge becomes low. System components are as follows:

  1. A superheat shut-off switch located in the compressor rear head.
  2. A thermal limiter assembly located in the engine compartment and connected to the super-heat switch.
  3. A wire assembly which connects the protection system in series with the compressor clutch coil circuit (see wiring schematic in this article).

The superheat switch is sensitive to both low-side suction pressures and suction gas temperatures. The switch senses low refrigerant charge conditions and causes a fuse link in the thermal limiter to blow, opening the compressor clutch coil circuit and rendering the compressor inoperative.