Test 12C - Bus Short To 5 Volts
NOTE:
For connector terminal identification see CONNECTOR IDENTIFICATION
. For wiring diagrams, see WIRING DIAGRAMS
. Perform VERIFICATION TEST VER-1A
after each repair.
CAUTION:
Always turn ignition off prior to disconnecting any module connector.
- Turn ignition off. Using external ohmmeter, measure resistance between Body Control Module (BCM) Black connector "A" terminal No. 3 (Violet/Brown wire) and Gray connector "B" terminal No. 78 (Light Green/Red wire). If resistance is less than 5 ohms, repair short between Violet/Brown wire and Light Green/Red wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminal No. 34 (White/Black wire) and Gray connector "B" terminal No. 78 (Light Green/Red wire). If resistance is less than 5 ohms, repair short between White/Black wire and Light Green/Red wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminals No. 3 (Violet/Brown wire) and No. 4 (Light Blue wire). If resistance is less than 5 ohms, repair short between Violet/Brown wire and Light Blue wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminals No. 4 (Light Blue wire) and No. 34 (White/Black wire). If resistance is less than 5 ohms, repair short between Light Blue wire and White/Black wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminal No. 3 (Violet/Brown wire) and Gray connector "B" terminal No. 79 (Tan wire). If resistance is less than 5 ohms, repair short between Violet/Brown wire and Tan wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminal No. 34 (White/Black wire) and Gray connector "B" terminal No. 79 (Tan wire). If resistance is less than 5 ohms, repair short between White/Black wire and Light Green/Red wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminal No. 3 (Violet/Brown wire) and Gray connector "B" terminal No. 48 (Tan/Red wire). If resistance is less than 5 ohms, repair short between Violet/Brown wire and Tan/Red wire. If resistance is 5 ohms or more, go to next step.
- Measure resistance between BCM Black connector "A" terminal No. 34 (White/Black wire) and Gray connector "B" terminal No. 48 (Tan/Red wire). If resistance is less than 5 ohms, repair short between White/Black wire and Tan/Red wire. If resistance is 5 ohms or more, replace BCM.