Quick-Connect Fittings: Removal
When disconnecting a quick-connect fitting, the retainer will remain on the fuel tube nipple.
WARNING:
RELEASE FUEL SYSTEM PRESSURE BEFORE DISCONNECTING A QUICK-CONNECT FITTINGS. REFER TO THE FUEL SYSTEM PRESSURE RELEASE PROCEDURE.
- Disconnect negative cable from battery.
- Perfom Fuel Pressure Release Procdure. Refer to the FUEL SYSTEM PRESSURE RELEASE .
- Squeeze retainer tabs together and pull fuel tube/quick-connect fitting assembly off of fuel tube nipple. The retainer will remain on fuel tube.