LEMON Manuals: Even more car manuals for everyone
Home >> Plymouth >> 1996 >> Voyager Base, 2.4 B >> Repair and Diagnosis >> Electrical >> Starter >> Starting System >> Starter Specifications

Starter Specifications

STARTER SPECIFICATIONS

Application Specification
Cranking Amperage Draw (1)
Caravan, Town & Country & Voyager 150-200 Amps
Cranking Voltage
Diesel Engines 8 Volts
Gasoline & CNG Engines 7.5 Volts
Free-Running Test
Voltage 11 Volts
Amperage 73 Amps
Minimum Speed 3401 RPM
(1) With engine at normal operating temperature. High viscosity oil, extreme cold temperatures, or tight engine will increase amperage draw.