| 11 |
IGN Reference Signal |
No distributor reference signal pickup during cranking. |
| 12 |
Number of Key-Ons Since Last Fault Or Since Faults Were Released |
Direct battery input to SBEC was disconnected within last 50-100 ignition key-ons. |
| 13 |
Map Pneumatic Signal |
No difference in MAP sensor signal is detected. |
| 13 |
Map Pneumatic Change |
No difference is detected between MAP reading & stored barometric pressure reading. |
| 14 |
Map Voltage Too Low |
MAP sensor input less than minimum acceptable voltage. |
| 14 |
Map Voltage Too High |
MAP sensor input more than maximum acceptable voltage. |
| 15 |
Vehicle Speed Signal |
No distance sensor signal detectedwith road load conditions. |
| 17 |
Low Engine Temp |
Coolant temperature stays below normal operating temperature during vehicle operation. |
| 21 |
O2 Sensor Signal |
No rich or lean signal is detectedfrom O2 sensor input. |
| 21 |
O2 Sensor Shorted Hi |
Oxygen sensor input voltage maintained above normal operating range. |
| 22 |
Coolant Voltage Low |
Coolant temperature sensor input below minimum acceptable voltage. |
| 22 |
Coolant Voltage High |
Coolant temperature sensor input above maximum acceptable voltage. |
| 23 |
Charge Temp Volt Low |
Charge temperature sensor input below minimum acceptable voltage. |
| 23 |
Charge Temp Volt Hi |
Charge temperature sensor input above maximum acceptable voltage. |
| 24 |
TPS Voltage Low |
TPS sensor output less than minimum acceptable voltage. |
| 24 |
TPS Voltage High |
TPS sensor output more than maximum acceptable voltage. |
| 25 |
AIS Motor Circuits |
Shorted condition detected in one or more Auto Idle Speed control circuits. |
| 27 |
INJ 1 Control Circuit |
INJ 1 injector bank output driver stage does not respond correctly to SBEC control signal. |
| 27 |
INJ 2 Control Circuit |
INJ 2 injector bank output driver stage does not respond correctly to SBEC control signal. |
| 27 |
INJ 3 Control Circuit |
INJ 3 injector bank output driver stage does not respond correctly to SBEC control signal. |
| 27 |
INJ 4 Control Circuit |
INJ 4 injector bank output driver stage does not respond correctly to SBEC control signal. |
| 31 |
Purge Solenoid Ckt |
Open or shorted condition is detected in purge purge solenoid circuit. |
| 33 |
A/C Clutch Relay Ckt |
Open or shorted condition detected in A/C clutch relay circuit. |
| 34 |
S/C Servo Solenoids |
Open or shorted condition detected in speed control vacuum or vent solenoid circuits. |
| 35 |
Radiator Fan Relay |
Open or shorted condition detected in radiator fan relay circuit. |
| 36 |
VNT Solenoid #3 Ckt |
Open or shorted condition detected in VNT solenoid No. 3 circuit. |
| 37 |
PTU Solenoid Circuit |
Open or shorted condition detected in torque converter part throttle unlock solenoid circuit. |
| 41 |
Alternator Field Ckt |
Open or shorted condition detected in alternator field circuit. |
| 42 |
Z1 Voltage Sense |
No battery voltage sensed when ASD relay is energized. |
| 45 |
Boost Limit Exceeded |
MAP reading above overboost limit detected during engine operation. |
| 46 |
Battery Voltage High |
Battery voltage sense input more than target charging voltage during engine operation. |
| 47 |
Charging Output Low |
Battery voltage sense input less than target charging voltage during engine operation and no significant change in voltage detected during active test of alternator output. |
| 51 |
Lean F/A Condition |
O2 sensor input indicates lean air/fuel ratio during engine operation. |
| 52 |
Rich F/A Condition |
O2 sensor input indicates rich air/fuel ratio during engine operation. |
| 53 |
Internal Self-Test |
SBEC detects internal failure. |
| 54 |
Sync Pick-Up Signal |
No high data rate detected during engine rotation. |
| 55 |
|
Completion of fault code display by check engine light. |
| 61 |
Baro Read Solenoid |
Open or shorted condition detected in baro read solenoid circuit. |
| 62 |
EMR Miles Not Stored |
Unsuccessful attempt to update EMR mileage in SBEC EEPROM (trucks only). |
| 63 |
EEPROM Write Denied |
Unsuccessful attempt to write to an EEPROM location by SBEC. |
| N/A |
Fault Code Error |
DRB-II does not recognize fault identification |
| 64 |
VNT Solenoid #1 Ckt |
Open or shorted condition detected in VNT solenoid No. 1 circuit. |
| 65 |
VNT Solenoid #2 Ckt |
Open or shorted condition detected in VNT solenoid No. 2 circuit. |
| 67 |
VNT A-Side Control |
MAP reading above boost goal for an extended time period. |