Rectifier Test
- Separate positive diode leads from negative diode leads. Using a volt/ohmmeter, test for continuity from positive heat sink to each of the positive diode leads. See Fig 1.
- Reverse volt/ohmmeter test leads and repeat test. The test should show continuity in one direction only. Test for continuity from negative heat sink to each of the negative diode leads.
- Reverse volt/ohmmeter test leads and repeat test. The test should show continuity in one direction only. If failure is detected in either test, replace rectifier assembly.
Courtesy of CHRYSLER MOTORS.