Turbo Models Only
Remove sensor from engine. At 70°F (20°C), measure resistance between terminals. Resistance should be 35 ohms. Check for less than one ohm resistance between terminal No. 47 and ground. Raise sensor temperature above 110°F (40°C). Ohmmeter should indicate infinity. Replace sensor if sensor does not work as indicated.