Control ELECTROVALVES: Operation
- Raise vehicle and support so wheels can be rotated. Turn ignition on. Wait until pump stops operating. Turn ignition off. Connect a jumper wire between ECU terminals No. 2 and 8.CAUTION: DO NOT energize electrovalves more than 60 seconds.
- Connect a jumper wire between ECU terminal No. 3 and the following terminals: No. 16, 17, 33, 24 and 35, one at a time. Depress brake pedal each time jumper wire is connected. Left front wheel should be locked. Turn ignition on. Left front wheel should be free. Turn ignition off.
- Connect jumper wire between ECU terminal No. 3 and each of the following terminals: No. 15, 16, 17, 33 and 34, one at a time. Same results from left front wheel should exist for right front wheel during this test.
- Perform same test for rear wheels, connecting jumper wire between ECU terminal No. 3 and the following terminals: No. 17 and 33, one at a time. If system fails any of these tests, replace check continuity of wiring. If wiring is okay, replace electrovalve/master cylinder assembly and retest.