Main ELECTROVALVE: Resistance
Using an ohmmeter, check resistance between ECU terminals No. 11 and 18. If resistance is not 2-5 ohms, check wiring continuity between ECU and electrovalve connector. If there is continuity, replace electrovalve/master cylinder assembly and retest.