Installation Procedure
- Install the ignition switch bracket to the ignition switch.
- Install the bolts to the ignition switch bracket. Tighten the bolts to 6 Nm (53 lb in).
- Install the ignition switch into position through the IP cluster opening.
- Connect the electrical connectors to the ignition switch.
- Connect the pass lock electrical connector from the ignition switch.
- Connect the park/lock cable to the ignition switch.
- Install the bolts to the ignition switch. Tighten the ignition switch bolts to 6 Nm (53 lb in).
- Insert the key and turn the ignition switch lock cylinder to the ACC position.
- Align and press ignition switch lock cylinder into place.
- If the ignition switch lock cylinder previously removed was seized or would not rotate, perform the following procedures:
- Install the new ignition switch lock cylinder as required by rotating both the cylinder and the ignition switch to the ON position.
- Push the ignition switch lock cylinder into the ignition switch housing until fully seated.
- It may be necessary to slightly depress the release button as it passes by the 9/32-inch hole previously drilled in the ignition switch housing.
- Remove the key from the ignition switch.
- Install the IP cluster.
- Install the HVAC control head.
- Install the radio.
- Connect the negative battery cable.
IMPORTANT:
Ignition switch lock cylinder may previously have not rotated or was seized.