Circuit Description
BCM receives and continuously monitors ground signal from circuit No. 1750 (Black wire). DTC will set when BCM detects an open in circuit No. 1750 (Black wire) or is open internally for longer than 0.3 second. No driver warning message will be displayed.
If conditions for malfunction no longer exist, history DTC will clear after 100 consecutive ignition cycles. DTC B0828 will also clear when conditions no longer exist or scan tool is used to clear codes.