Hydraulic System Bleeding
- Raise and support front of vehicle. Ensure front tires are off ground. With engine off, use steering wheel to turn front wheels to full left position. Fill pump reservoir to FULL COLD mark.
- Turn front wheels from side to side several times without hitting stops. Maintain pump reservoir fluid level at FULL COLD mark. When pump reservoir fluid is clear and free of bubbles, start engine and recheck fluid level. Add fluid if necessary.
- Lower vehicle and idle engine for 2-3 minutes. Ensure no fluid leaks exist. Road test vehicle to ensure power steering system is functioning properly. After road test, ensure fluid level is at FULL HOT mark, and system has no fluid leaks.