BCM Data Parameters:: BD24
Air delivery mode (AIR MODE) displayed as a number from 0 to 12. Each number is code which represents the following air delivery modes:
- 0 - Auto-Recirc Upper outlets
- 1 - Auto-outside Upper outlets
- 2 - Auto-Bi-Level outlets
- 3 - Auto-Heater-Defog outlets
- 4 - Auto-Lower outlets
- 5 - OFF
- 6 - Normal purge
- 7 - Cold (DEF) purge
- 8 - Defog
- 9 - Forced (FAN) Lower outlets
- 10 - Forced (FAN) Upper outlets
- 11 - Forced (FAN) Bi-level outlets
- 12 - Forced (FAN) De-fog outlets