BCM Output Parameters:
- BO00 CYCLE NONE will display and will not show HI or LO. This is normal resting code where no outputs will be cycled.
- BO01 Cruise control vent solenoid (C/C VENT) display is HI when vent solenoid is ON (energized). Cruise ON/OFF switch must be ON for output to cycle.
- BO02 Cruise control vacuum solenoid (C/C VAC) display is HI when vacuum solenoid is ON (energized). Cruise ON/OFF switch must be ON for output to cycle.
- BO04 Courtesy lamps (COURT LMPS) display is LO when relay is ON (energized).
- BO05 Twilight relay (TWILIGHT) display is LO when relays are ON (energized).
- BO10 CHIME 1 display is LO when fast chime is ON (sounding).
- BO11 CHIME 2 display is LO when slow chime is ON (sounding).
- BO12 DRL FG LMP display is LO when foglights (DRL) are ON.
- BO13 DIS CLOCK display is LO when clock line voltage is LO.