Vacuum Circuit Short (Test H)
Remove servo connector. Check resistance between terminals "C" and "E" of servo. If resistance is less than 30 ohms, replace servo. If resistance is 30 ohms or more, check for a short to ground in wire from terminal "C" of module to terminal "A" of servo.