Code 13, Open Oxygen Sensor Circuit: Notes
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- The following conditions must exist to set a Code 13:
- Engine running at least 40 seconds after start.
- Engine coolant temperature greater than 108.5°F (42.5°C).
- Code 21 or 22 must not be set.
- Oxygen sensor voltage steady between .34 and .55 volt.
- TPS signal greater than 6 percent for more time than less than 6% or about .3 volt greater than closed throttle voltage.
- Conditions must be met and held for at least 20 seconds.
- This test will indicate whether sensor is faulty, or if wiring and/or ECM is cause of Code 13.NOTE: Use only high impedance digital volt/ohmmeter for this test.
- This test checks for continuity of circuits No. 412 and 413. If circuit No. 413 is open, ECM voltage on circuit No. 412 will be greater than .6 volt (600mV).