Code 33, Map Sensor Signal Volt Hi: Notes
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- The following conditions must be met to set a Code 33:
- MAP signal greater than 80 kPa.
- TPS reading below 12 percent.
- VSS reading below one MPH.
- Above conditions met for 5 seconds.
- With MAP sensor unplugged, ECM terminal "YD15" voltage should be low if ECM and wiring are okay.