Work Procedure
CAUTION:
Always use CONSULT for the side G sensor calibration. (It cannot be adjusted other than with CONSULT.)
- CHECK THE VEHICLE STATUS
- Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
- Stop the engine.
- Ignition OFF (Auto ACC function OFF).
Is the vehicle stopped in the straight-ahead position on level surface?
YES
GO TO 2.
NO
Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
- PERFORM SIDE G SENSOR CALIBRATION CAUTION:
- Never allow passenger or load on the vehicle.
- Never apply vibration to the vehicle body when opening or closing door during calibration.
CONSULT
- Ignition ON.CAUTION: Never start engine.
- Select "ABS ", "Work support ", "DECEL G SENSOR CALIBRATION " in this order.
- Select "START ".
- After approximately 10 seconds, select "END ".
- Ignition OFF (Auto ACC function OFF) and then it ON again.CAUTION: Be sure to perform the operation above.
GO TO 3.
- CHECK DATA MONITOR
CONSULT
- Drive the vehicle. Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface.
- Select "ABS ", "Data Monitor ", and "Side G sensor " in this order. Check that the signal is within the specified value. Refer to Reference Value .
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 1.
- ERASE SELF-DIAGNOSIS MEMORY
CONSULT
Erase self-diagnosis result of all systems.
Are the memories erased?
YES
Inspection End.
NO
Check the items indicated by the self-diagnosis.